How to read the result
- What each term means: Q is the peak flow, C the share of the rain that runs off, I the rainfall intensity and A the drainage area. For 5 ac of single-family housing (C = 0.400) in 3 in/h of rain the peak flow is 6.05 ft³/s. Double the rainfall to 6 in/h and it doubles to 12.10 ft³/s: the flow is proportional to each of the three terms.
- The runoff coefficient is a range: HEC-22 Table 4.1 gives single-family areas 0.30 to 0.50. The page uses the middle (0.400) unless you choose an end, and always shows the flow at both ends: 4.54 ft³/s to 7.56 ft³/s here. The table footnote says higher values suit steeper slopes and less frequent storms.
- A mix of land uses: a site of 3 ac single-family housing and 2 ac of asphalt has a weighted C of 0.570 (HEC-22 equation 4.2), so the same 3 in/h gives 8.62 ft³/s. A typed C is available if your agency gives its own.
- The rainfall is yours to supply: intensity depends on the place, the storm frequency and the time of concentration. Take it from your agency IDF curve or NOAA Atlas 14. The page does not look it up.
- Solving backwards: with 10 ft³/s allowed at 3 in/h, single-family housing can drain at most 8.26 ac.
- Small areas only: HDS-2 recommends the method below 200 ac (80 ha). The page warns above that.
- What this page leaves out: time of concentration, runoff volume, detention, pipe, inlet and culvert sizing, and the rules of your local agency, which may need other C values or a frequency factor. HEC-22 says FHWA does not endorse the frequency factor, so none is applied.
To check whether a gravity pipe can carry the peak flow, use the Pipe Flow Calculator, and to set the fall of the drain, the Pipe & Drain Slope Calculator. To turn a site's dimensions into acres first, use the Acreage Calculator. This page gives the peak flow only: it does not find the rainfall, the time of concentration, the volume or the size of a pond or pipe, and your local agency's manual governs a design submittal.
Worked example
A 5 ac residential block of single-family housing (HEC-22 Table 4.1: C from 0.30 to 0.50) gets a design rainfall of 3 in/h from the local IDF curve. We take the middle of the range, C = 0.400.
- Area = 5 ac = 2.0234 ha; rainfall = 3 in/h = 76.2 mm/h
- C = (0.30 + 0.50) ÷ 2 = 0.400
- Q = C × I × A ÷ 360 = 0.400 × 76.2 × 2.0234 ÷ 360 = 0.171 m³/s = 6.05 ft³/s (2,715 gpm)
- At the low end of the range (C = 0.30): 4.54 ft³/s; at the high end (C = 0.50): 7.56 ft³/s
- Mix instead: 3 ac single-family and 2 ac asphalt, weighted C = (0.40 × 3 + 0.825 × 2) ÷ 5 = 0.570, so Q = 8.62 ft³/s
- Solving the other way: with 10 ft³/s allowed at the same rainfall, the area can be at most 8.26 ac
The page converts with the exact factor (1 ha · 1 mm/h = 1/360 m³/s). HEC-22 prints the customary-units form with Ku = 1.0, which is 0.83% lower than the exact value (1.00833); for HEC-22 Example 4.3 (C 0.315, 2.3 in/h, 43.3 ac) the manual gives 31.4 ft³/s and this page gives 31.6 ft³/s.
These are the same numbers the calculator shows when it first loads.
Method and formulas
Q = C · I · A ÷ Ku (Ku = 1.0 for ft³/s, in/h and ac in HEC-22; 360 for m³/s, mm/h and ha)
A = Q · Ku ÷ (C · I) and I = Q · Ku ÷ (C · A)
C = Σ (Cx · Ax) ÷ Atotal
- Q
- Peak flow, in ft³/s (m³/s)
- C
- Dimensionless runoff coefficient from Table 4.1, or the value you type
- I
- Rainfall intensity, in in/h (mm/h), for the time of concentration and the storm frequency you design for
- A
- Drainage area, in acres (hectares)
- Cx, Ax
- Coefficient and area of each land use in a mix
The FHWA manual (HEC-22, section 4.2.2) gives the Rational Method as equation 4.1, Q = CIA ÷ Ku, and the area-weighted coefficient as equation 4.2. The page computes in SI with Ku = 360, which is exact for hectares and millimetres per hour, and converts, so the US and metric inputs always give the same physical result. The manual rounds Ku to 1.0 for acres and inches per hour; the exact factor is 1.00833, so the page reads 0.83% higher than a hand calculation with 1.0. Solving for the area or the rainfall uses the same equation rearranged, so the three modes agree exactly.
The manual lists what the method assumes: the whole watershed contributes at the peak, the rainfall is the same over the area and steady for the time of concentration, the peak has the frequency of the rainfall, and C is the same for every storm. It notes that some agencies apply a frequency-of-event correction factor to C and that FHWA does not endorse it; the page applies none.
Assumptions and limits
- The five assumptions HEC-22 lists: the whole watershed contributes at the peak; rainfall intensity is the same over the area and uniform for a time equal to the time of concentration; the peak has the same frequency as the rainfall; C is the same for all storms.
- The reader supplies the rainfall intensity for the chosen location, storm frequency and time of concentration; the page does not estimate it.
- C is read from HEC-22 Table 4.1 (ASCE 1960) at the low end, middle or high end of its range, or typed by the reader.
- Several land uses are combined by area weighting (eq 4.2).
- Solving for area or intensity uses the same equation rearranged, so the three modes agree.
- Peak flow only: no hydrograph, no runoff volume, no detention or pipe sizing.
- Small drainage areas: HDS-2 recommends the method below 200 ac (80 ha); the page warns above that.
- Table 4.1 gives ranges, not exact values; the page shows the flow at both ends of the range so the effect of the choice is visible.
- No rainfall data and no time of concentration calculation: the reader brings the intensity from a local IDF curve or NOAA Atlas 14.
- Local agencies may require other C values, frequency factors or a different method: their manual governs a design submittal.
- Not a code check or a drainage design: a screening estimate to be checked against the agency manual.
Reference tables
| Land use or surface | C |
|---|---|
| Business, downtown areas | 0.70 to 0.95 |
| Business, neighborhood areas | 0.50 to 0.70 |
| Residential, single-family areas | 0.30 to 0.50 |
| Residential, multi-units detached | 0.40 to 0.60 |
| Residential, multi-units attached | 0.60 to 0.75 |
| Residential, suburban | 0.25 to 0.40 |
| Apartment dwelling areas | 0.50 to 0.70 |
| Industrial, light areas | 0.50 to 0.80 |
| Industrial, heavy areas | 0.60 to 0.90 |
| Parks, cemeteries | 0.10 to 0.25 |
| Playgrounds | 0.20 to 0.40 |
| Railroad yard areas | 0.20 to 0.40 |
| Unimproved areas | 0.10 to 0.30 |
| Lawn, sandy soil, flat 2% | 0.05 to 0.10 |
| Lawn, sandy soil, average 2 to 7% | 0.10 to 0.15 |
| Lawn, sandy soil, steep 7% | 0.15 to 0.20 |
| Lawn, heavy soil, flat 2% | 0.13 to 0.17 |
| Lawn, heavy soil, average 2 to 7% | 0.18 to 0.22 |
| Lawn, heavy soil, steep 7% | 0.25 to 0.35 |
| Street, asphaltic | 0.70 to 0.95 |
| Street, concrete | 0.80 to 0.95 |
| Street, brick | 0.70 to 0.85 |
| Drives and walks | 0.75 to 0.85 |
| Roofs | 0.75 to 0.95 |
Source: Federal Highway Administration, Urban Drainage Design Manual, Hydraulic Engineering Circular No. 22 (HEC-22), 4th Edition (2024), section 4.2.2, equations 4.1 and 4.2, Table 4.1 (runoff coefficients for the Rational Method, ASCE 1960). Higher values are generally appropriate for steeply sloped areas and less frequent storms, because infiltration and other losses have a proportionally smaller effect on runoff in these cases.
| Area | 1 in/h | 2 in/h | 3 in/h | 4 in/h | 6 in/h |
|---|---|---|---|---|---|
| 1 ac | 0.4 | 0.8 | 1.2 | 1.6 | 2.4 |
| 5 ac | 2.0 | 4.0 | 6.1 | 8.1 | 12.1 |
| 10 ac | 4.0 | 8.1 | 12.1 | 16.1 | 24.2 |
| 25 ac | 10.1 | 20.2 | 30.3 | 40.3 | 60.5 |
| 50 ac | 20.2 | 40.3 | 60.5 | 80.7 | 121.0 |
Source: Federal Highway Administration, Urban Drainage Design Manual, Hydraulic Engineering Circular No. 22 (HEC-22), 4th Edition (2024), section 4.2.2, equations 4.1 and 4.2, Table 4.1 (runoff coefficients for the Rational Method, ASCE 1960). Flows worked out by the EngiFormula engine.
| Land use or surface | C range | Peak flow, low to high end |
|---|---|---|
| Business, downtown areas | 0.70 to 0.95 | 10.59 to 14.37 ft³/s |
| Residential, single-family areas | 0.30 to 0.50 | 4.54 to 7.56 ft³/s |
| Residential, suburban | 0.25 to 0.40 | 3.78 to 6.05 ft³/s |
| Street, asphaltic | 0.70 to 0.95 | 10.59 to 14.37 ft³/s |
| Drives and walks | 0.75 to 0.85 | 11.34 to 12.86 ft³/s |
| Roofs | 0.75 to 0.95 | 11.34 to 14.37 ft³/s |
| Lawn, heavy soil, average 2 to 7% | 0.18 to 0.22 | 2.72 to 3.33 ft³/s |
| Parks, cemeteries | 0.10 to 0.25 | 1.51 to 3.78 ft³/s |
| Unimproved areas | 0.10 to 0.30 | 1.51 to 4.54 ft³/s |
Source: Federal Highway Administration, Urban Drainage Design Manual, Hydraulic Engineering Circular No. 22 (HEC-22), 4th Edition (2024), section 4.2.2, equations 4.1 and 4.2, Table 4.1 (runoff coefficients for the Rational Method, ASCE 1960). Flows worked out by the EngiFormula engine. Each flow is C × I × A for the two ends of the range.
Charts and diagrams
Show chart data as a table
| Rainfall intensity (in/h) | Asphaltic street | Single-family | Lawn, heavy soil, 2 to 7% |
|---|---|---|---|
| 0.5 | 2.08 | 1.01 | 0.5 |
| 1 | 4.16 | 2.02 | 1.01 |
| 2 | 8.32 | 4.03 | 2.02 |
| 3 | 12.48 | 6.05 | 3.03 |
| 4 | 16.64 | 8.07 | 4.03 |
| 5 | 20.8 | 10.08 | 5.04 |
| 6 | 24.96 | 12.1 | 6.05 |
Source: Calculated with the EngiFormula Rational Method engine (method v1.0): Q = C I A ÷ Ku in SI (Ku = 360 with A in ha and I in mm/h), with the middle of each Table 4.1 range and an area of 5 ac. 1 acre = 43,560 ft² and 1 inch = 25.4 mm exactly, from NIST Special Publication 811 (2008 edition), Appendix B.
Common uses
Sizing checks for a lot or a small site
Get a peak flow to compare with a pipe, a swale or a pond outlet before the detailed design.
Before and after development
Run the existing land use and the proposed mix with the same rainfall to see how much the peak flow rises.
Roofs and paved areas
Find the runoff of a roof, a driveway or a car park, with the C of the surface from the table.
Finding the largest area a pipe can serve
Solve for the area that a pipe or outlet capacity allows at your design rainfall.
Checking another tool
The working shows each step, so you can compare C, the weighting and the flow with a spreadsheet or the agency manual.
Frequently asked questions
What is the Rational Method?
It is a simple formula for the peak flow of runoff from a small drainage area: Q = C × I × A. In the default case, 5 ac with C = 0.400 in 3 in/h of rain gives 6.05 ft³/s. It assumes that the whole area contributes at the peak and that the rain is steady and uniform.
How do you calculate peak runoff with the Rational Method?
Pick C for the land use, take the rainfall intensity for your place and design storm, and multiply by the area. In metric units divide by 360 when the area is in hectares and the rainfall in millimetres per hour. The working under the calculator shows each step.
What runoff coefficient (C) should I use?
Use the line of the table that matches the land use: for example 0.30 to 0.50 for single-family areas, 0.70 to 0.95 for asphalt streets and 0.75 to 0.95 for roofs (HEC-22, Table 4.1). Higher values suit steeper slopes and less frequent storms. The range matters: for the default case the flow runs from 4.54 to 7.56 ft³/s across the single-family range.
How do you find a weighted runoff coefficient for mixed land use?
Multiply each land use's C by its area, add them up and divide by the total area (HEC-22 equation 4.2). For 3 ac of single-family housing and 2 ac of asphalt the weighted C is 0.570. The calculator does this for up to four land uses.
Where do I get the rainfall intensity?
From the intensity-duration-frequency (IDF) curves of your local agency, or from NOAA Atlas 14 in the United States, for your storm frequency and the time of concentration of the area. HEC-22 section 4.2.2.2 describes this. The page does not look it up, so it cannot give you a wrong location.
What is the maximum drainage area for the Rational Method?
HDS-2, as quoted in HEC-22, recommends the method for areas smaller than 200 ac (80 ha). The page warns above that size.
Should I apply a frequency factor to C for large storms?
HEC-22 says that FHWA does not endorse a frequency-of-event correction factor, so the page applies none. Some local agencies require one; if yours does, type the adjusted C yourself.
What is the difference between the Rational Method and the modified Rational Method?
This page gives the peak flow only, as in HEC-22. The modified Rational Method is a variation that also builds a simple hydrograph and a runoff volume for storage design; this page does not do that.
Sources and references
- Federal Highway Administration, Urban Drainage Design Manual, Hydraulic Engineering Circular No. 22 (HEC-22), 4th Edition (2024): section 4.2.2 (Rational Method, equations 4.1 and 4.2, assumptions, the 200 ac limit from HDS-2 and the frequency-of-event factor), Table 4.1 (runoff coefficients for the Rational Method, ASCE 1960) and section 4.2.2.2 (rainfall intensity).
- NIST Special Publication 811, Guide for the Use of the International System of Units (SI), 2008 edition, Appendix B (exact values for the inch, foot and acre).
About this calculator
Scope and disclaimer
The Rational Method peak flow, with C from the HEC-22 table (one land use or an area-weighted mix) or typed by the reader, solving for flow, area or rainfall intensity. It is not a rainfall lookup, a time of concentration, volume, detention, pipe, inlet or culvert design tool.
This calculator gives information and preliminary estimates only. It is not professional design advice and does not replace the governing code, product instructions or a qualified professional's judgement for your project.