Total Dynamic Head Calculator

Enter the flow, the lift, the pressure you need at the outlet and the pipe, to get the total dynamic head to read on a pump curve, the water power and, with an efficiency you enter, the shaft power.

  • Every part of the head shown
  • Outlet pressure and equipment loss
  • Cited method (NRCS)
  • No assumed efficiency
  • US and metric

Enter the lift, the pipe and the flow

Units
gpm
ft
psi
in
ft
ft of head
°F
%

Negative if the water is delivered lower than the source level. Measure to the outlet, or to the water surface of the tank you fill above it.

For example the pressure a sprinkler, filter or pressure tank needs. 0 for an open outlet.

Use the inside diameter of the pipe, not the nominal size.

Add up the K values for your fittings from your supplier or your design. Left at 0, only the straight pipe is counted. The page does not supply K values.

From the maker’s data at your flow. The page does not supply equipment losses. 1 psi of water is 2.31 ft.

The NRCS handbook says velocity head is small in most applications and is usually ignored. Turn it on for high velocities.

From the pump curve at your flow. Needed only for shaft power. The page assumes none.

Total dynamic head (TDH)

62.9 ft

TDH as water pressure
27.2 psi
Static head (lift)
50.0 ft
Pressure head at the outlet
0.00 ft
Friction head, pipe and fittings
12.9 ft
Other equipment head
0.00 ft
Velocity head
0.00 ft (left out)
Mean velocity in the pipe
6.13 ft/s
Flow regime
Turbulent
Hydraulic (water) power
0.952 hp
Shaft power at your efficiency
Enter a pump efficiency

The pump must deliver a total dynamic head of 62.9 ft, about 27.2 psi of water pressure: 50.0 ft of lift, 0.00 ft for outlet pressure, 12.9 ft of friction in the pipe and fittings and 0.00 ft of other equipment. The water power is 0.952 hp. Read this head at your flow on the pump curve.

Show the working

  1. Velocity = flow ÷ area = flow ÷ (π × (2 in)² ÷ 4) = 6.13 ft/s
  2. Water at 68 °F has a density of 998.1 kg/m³ and a viscosity of 1.002 mPa·s. Reynolds number = density × velocity × diameter ÷ viscosity = 94,507
  3. Roughness ε = 0.002 mm for PVC, PE or HDPE plastic pipe; ε ÷ D = 0.00003937
  4. Friction factor, turbulent flow: Colebrook-White, solved by iteration from the Swamee-Jain estimate: f = 0.01841
  5. Straight pipe: head loss = f × (200 ft ÷ 2 in) × velocity² ÷ (2 × 9.80665) = 12.89 ft
  6. Static head (lift from the source level to the delivery point) = 50.0 ft
  7. Total dynamic head = static + pressure + friction (pipe and fittings) = 62.9 ft
  8. Water power = density × g × flow × TDH ÷ 745.7 W per hp = 0.952 hp

What you can do with this calculator

  1. Total dynamic head calculator. Enter lift, flow and pipe to get the head the pump must deliver.
  2. Add pressure and equipment loss. Include outlet pressure and filter or heater loss from the maker’s data.
  3. See the power needed. Water power, and shaft power if you enter the pump’s efficiency.
  4. See how a bigger pipe helps. Friction and head fall as the pipe grows.

How to read the result

  • What each part of the head is: the static head is the vertical lift from the water level you pump from to where the water is delivered (50.0 ft here). The pressure head is the outlet pressure you need, changed into feet of water: 1 psi of water is 2.31 ft. The friction head is what the pipe wall and the fittings take away (12.9 ft here), and the equipment head is the loss of a filter, heater or check valve that you type in. They add up to the total dynamic head: 62.9 ft.
  • Why a bigger pipe helps, but only on the friction part: the lift does not change with the pipe. The friction grows with the square of the velocity, so the same 60 gpm in a 3 in pipe instead of a 2 in pipe runs at 2.72 ft/s instead of 6.13 ft/s and the total falls from 62.9 ft to 51.8 ft.
  • How to read the result against a pump curve: look up the total dynamic head at your flow on the pump maker’s curve. A pump whose curve passes through that point, at or near its best efficiency, will deliver your flow. Many designers add a margin for wear and for the uncertainty of the pipe roughness; the page adds none.
  • Outlet pressure: if the water has to arrive at a pressure, for example 20 psi for a sprinkler, add it in the pressure box. In the default case 20 psi adds 46.2 ft and takes the total to 109.1 ft.
  • Velocity head: it is off by default. The NRCS handbook says it is small in most applications and is usually ignored. Turn it on to add v² ÷ 2g; here that is 0.6 ft on top of 62.9 ft.
  • What this page does not check: suction conditions and NPSH, the operating point on a system curve, the choice of the pump, or fire-pump and sprinkler duties. Fittings and equipment losses are typed by you, because they depend on the product; the page supplies no K values or equipment losses.

To see the friction part of the head in more detail, with the smallest pipe for a pressure loss you allow, use the Pipe Friction Loss Calculator. If the pump fills a tank, the Tank Volume Calculator gives its capacity, and the Pipe Volume Calculator gives the water the pipe holds. This page gives a head and power estimate for water in one pipe size; it does not check suction conditions or NPSH, and it is not a pump selection or a fire-pump calculation.

Worked example

Pump 60 gpm of water at 68 °F (20 °C) up 50 ft, to an open outlet, through 200 ft of 2 in PVC pipe (suction and discharge together), no fittings, no equipment loss, velocity head left out.

  1. Flow = 60 gpm = 3.785 L/s; inside diameter = 2 in = 50.8 mm
  2. Velocity = flow ÷ (π × D² ÷ 4) = 6.13 ft/s (1.87 m/s); Reynolds number from the water at 20 °C: density 998.1 kg/m³, viscosity 1.002 mPa·s, turbulent
  3. Friction head, Darcy-Weisbach with the Colebrook-White factor f = 0.0184: f × (L ÷ D) × v² ÷ (2g) = 12.9 ft (3.93 m)
  4. Static head = 50.0 ft (15.2 m); pressure head = 0 (open outlet); equipment head = 0
  5. Total dynamic head = 50.0 ft + 12.9 ft = 62.9 ft (19.2 m), about 27.2 psi of water pressure
  6. Water power = ρ × g × Q × TDH = 0.952 hp (0.710 kW)
  7. Shaft power, with a made-up efficiency of 65% (replace it with the figure on your pump curve) = 0.952 hp ÷ 0.65 = 1.47 hp

The same flow through a 3 in pipe runs at 2.72 ft/s and needs 51.8 ft of head, so the friction part falls from 12.9 ft to 1.84 ft while the 50.0 ft of lift stays. With a total fittings coefficient K of 6 in the 2 in pipe the friction part rises to 16.4 ft.

These are the same numbers the calculator shows when it first loads.

Method and formulas

TDH = Hstatic + Hpressure + Hfriction + Hequipment (+ v² ÷ 2g if you include velocity head)
Hpressure = p ÷ (ρ g) · Hfriction = (f × L ÷ D + ΣK) × v² ÷ (2g)
Water power Pw = ρ g Q TDH · Shaft power Ps = Pw ÷ η

TDH
Total dynamic head, in feet (metres) of water
Hstatic
Vertical distance from the source level to the delivery point; negative if the delivery is lower
p
Gauge pressure needed at the outlet
f, L, D, v
Darcy friction factor, total pipe length, inside diameter and mean velocity, as on the Pipe Friction Loss Calculator
K
Total loss coefficient of the fittings, typed by you
ρ, g
Density of water at your temperature and 9.80665 m/s²
Q, η
Flow rate and pump efficiency (a fraction); η is used only if you type it

The NRCS handbook (Chapter 8, section 623.0801) lists the parts of the total dynamic head as suction and discharge pipe friction, suction and discharge lift, system pressure, minor fitting loss and velocity head, and gives water horsepower as flow in gpm × head in ft × specific gravity ÷ 3,960, with brake horsepower as that divided by the pump efficiency. The page uses the same relations in SI with the density of water at the temperature you enter; for 20 °C water this differs from the 3,960 form by about 0.04%. Between a Reynolds number of 2,000 and 4,000 the page shows the friction head, the total and the power as a range, as the Pipe Friction Loss page does.

Assumptions and limits

  • One pipe size and material for the whole run (suction and discharge together), full and flowing at a steady rate.
  • A single liquid: water at the temperature entered; no slurry, gas or hot oil.
  • Static head is measured between the water level pumped from and the delivery point, so a flooded or a lifting suction both work.
  • Fittings enter as a total K, and filters, heaters and valves as a head, both typed by the reader; the page supplies none.
  • Velocity head is left out unless the reader turns "Include velocity head" on (the handbook says it is usually ignored).
  • A head and power estimate for choosing a pump from its curve; it is not a pump selection, system curve or design.
  • Does not check suction conditions (NPSH available against required), cavitation, water hammer, pump curves or the operating point.
  • Not a fire-pump or sprinkler-design calculation: those follow their own codes and acceptance tests.
  • Friction in the transition zone (Reynolds number 2,000 to 4,000) has no reliable value: the page shows a range, as on the Pipe Friction Loss page.
  • Ageing and scaling raise pipe roughness; allow margin when you choose the pump.

Reference tables

Friction head in feet per 100 ft of PVC pipe, water at 68 °F, by flow and inside diameter
Flow1.5 in2 in3 in4 in
20 gpm3.60.90.10.0
40 gpm12.43.10.40.1
60 gpm25.86.40.90.2
80 gpm43.410.81.50.4
100 gpm65.216.22.30.6

Source: Calculated with the EngiFormula pump head engine (method v1.0): static head plus Darcy-Weisbach friction with the Colebrook-White factor, PVC roughness 0.002 mm, water at 20 °C. 1 US gallon = 231 in³, 1 psi = 6,894.757 Pa, 1 hp = 550 ft·lbf/s, from NIST Special Publication 811 (2008 edition), Appendix B.

Pressure in psi and the equivalent head of water at 68 °F
Pressure (psi)Head (ft of water)Head (m of water)
511.63.52
1023.17.04
2046.214.09
3069.321.13
4092.428.18
60138.742.26
80184.956.35

Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 623 Irrigation, Chapter 8 Irrigation Pumping Plants, Amendment 78, January 2016, section 623.0801 (total dynamic head and water horsepower, pages 8-7 and 8-8), with the values worked out by the EngiFormula engine for water at 20 °C.

Water horsepower by flow and total dynamic head (before pump efficiency)
FlowTotal dynamic headWater power (hp)
20 gpm20 ft0.10
20 gpm60 ft0.30
20 gpm100 ft0.50
40 gpm20 ft0.20
40 gpm60 ft0.61
40 gpm100 ft1.01
60 gpm20 ft0.30
60 gpm60 ft0.91
60 gpm100 ft1.51
100 gpm20 ft0.50
100 gpm60 ft1.51
100 gpm100 ft2.52

Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 623 Irrigation, Chapter 8 Irrigation Pumping Plants, Amendment 78, January 2016, section 623.0801 (total dynamic head and water horsepower, pages 8-7 and 8-8), with the values worked out by the EngiFormula engine for water at 20 °C.

Absolute roughness of common pipe materials
MaterialRoughness ε (mm)Roughness ε (in)
PVC, PE or HDPE plastic pipe0.0020.0000787
Copper, brass or other drawn tubing0.00150.0000591
Commercial or welded steel0.0460.00181
Ductile iron0.0610.0024
Galvanized iron0.150.00591
Cast iron0.250.00984
Concrete, smooth end of the range (0.3 mm)0.30.0118
Concrete, rough end of the range (3 mm)30.118

Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 634 Hydraulics, Chapter 4 Pipe Flow, 1st Edition, February 2022, Figure 4-5 (absolute roughness). Concrete is given there as a range; both ends are listed. Inches are converted from millimetres at 25.4 mm per inch.

Charts and diagrams

Head build-up of the default job A single bar split into the static head, 50.0 ft, and the friction head, 12.9 ft, which together make the total dynamic head of 62.9 ft. Static head Friction head 50.0 ft12.9 ft Total dynamic head 62.9 ft
The default job to scale: the lift and the pipe friction add up to the total. Outlet pressure, equipment and velocity head are zero here and would be added to the right.
Total dynamic head against flow for three pipe sizes (50 ft of lift, 200 ft of pipe) Three curves start at the 50 ft of lift and rise with flow, and the smaller the pipe the steeper the curve. At 60 gpm the total is 62.9 ft in a 2 in pipe, 51.8 ft in a 3 in pipe and 50.5 ft in a 4 in pipe. 0255075100 0306090120 Flow (gpm) Total dynamic head (ft) 2 in 3 in 4 in
Three curves start at the 50 ft of lift and rise with flow, and the smaller the pipe the steeper the curve. At 60 gpm the total is 62.9 ft in a 2 in pipe, 51.8 ft in a 3 in pipe and 50.5 ft in a 4 in pipe.
Show chart data as a table
Total dynamic head against flow for three pipe sizes (50 ft of lift, 200 ft of pipe)
Flow (gpm) 2 in3 in4 in
10 50.5450.0850.02
20 51.8150.2650.07
30 53.7350.5450.14
40 56.2350.8950.23
50 59.2951.3350.34
60 62.8951.8450.46
80 71.6553.0850.78
100 82.4254.651.16
120 95.1456.3951.6

Source: Calculated with the EngiFormula pump head engine (method v1.0): static head plus Darcy-Weisbach friction with the Colebrook-White factor, PVC roughness 0.002 mm, water at 20 °C. 1 US gallon = 231 in³, 1 psi = 6,894.757 Pa, 1 hp = 550 ft·lbf/s, from NIST Special Publication 811 (2008 edition), Appendix B.

Common uses

Irrigation and water supply

Enter the lift, the pipe and the pressure the sprinklers or the emitters need to get the head to look up on the pump curve.

Filling a tank or a reservoir

Use the height to the top of the tank as the static head, and add the pressure only if the tank is closed.

Pool and spa pumps

Type the filter, heater and valve losses from their maker’s data in the equipment box. The page gives no equipment values of its own.

Comparing pipe sizes

Change the inside diameter and watch the friction head and the power change while the lift stays the same.

Checking a result from another tool

The working shows each step, so you can compare the head, the friction factor and the power with a spreadsheet or a pump maker’s sizing tool.

Frequently asked questions

What is total dynamic head?

It is the total energy, per unit weight of water, that a pump has to add to move the flow: the lift, the pressure needed at the outlet, the friction in the pipe and fittings, the loss of equipment in the line and, if you count it, the velocity head. For 60 gpm up 50 ft through 200 ft of 2 in PVC it is 62.9 ft.

How do you calculate total dynamic head?

Add the parts: TDH = static head + pressure head + friction head + equipment head. In the default case that is 50.0 ft of lift plus 12.9 ft of friction, for 62.9 ft, about 27.2 psi of water pressure. The working above the page shows each step.

What is the difference between static head and total dynamic head?

Static head is the lift alone, the vertical distance between the water levels. Total dynamic head adds the outlet pressure, the friction and the equipment loss, so it is always the larger number when water is flowing. Here the static head is 50.0 ft and the total is 62.9 ft.

How do I find the total dynamic head of a pool pump?

Use the same sum. Enter the lift (often near zero), the length and inside diameter of the pipe, the fittings as a total K, and type the filter, heater and valve losses from their maker’s data in the equipment box. The page does not supply equipment values, because they depend on the product and the flow.

How does pipe size change total dynamic head?

A larger pipe lowers the velocity, and friction grows with the square of the velocity, so the friction part drops fast. In the default case, a 3 in pipe instead of 2 in cuts the total from 62.9 ft to 51.8 ft. The lift stays the same.

How do I convert pressure in psi to feet of head?

Divide the pressure by the weight of water per unit volume. For water at 68 °F, 1 psi is 2.31 ft of head, so 20 psi is 46.2 ft. The pressure table above lists common values.

How much horsepower does my pump need?

The water power is flow × head × density × g; here it is 0.952 hp. The pump needs more at the shaft because it is not perfectly efficient: type the efficiency from the pump curve and the page divides by it. With a made-up 65% the shaft power would be 1.47 hp. The page assumes no efficiency until you enter one.

Does total dynamic head include NPSH?

No. NPSH is a separate check on the suction side, to make sure the pump does not cavitate. This page does not do that check, so confirm it with the pump maker’s NPSH required at your flow.

Sources and references

About this calculator

Method version: 1.0 Last technical update:

Scope and disclaimer

The total dynamic head and the hydraulic and shaft power for water in one pipe size, from lift, outlet pressure, pipe friction, fittings and equipment loss you enter. It is not a pump selection, NPSH, system-curve, fire-pump or design tool.

This calculator gives information and preliminary estimates only. It is not professional design advice and does not replace the governing code, product instructions or a qualified professional's judgement for your project.