How to read the result
- What each part of the head is: the static head is the vertical lift from the water level you pump from to where the water is delivered (50.0 ft here). The pressure head is the outlet pressure you need, changed into feet of water: 1 psi of water is 2.31 ft. The friction head is what the pipe wall and the fittings take away (12.9 ft here), and the equipment head is the loss of a filter, heater or check valve that you type in. They add up to the total dynamic head: 62.9 ft.
- Why a bigger pipe helps, but only on the friction part: the lift does not change with the pipe. The friction grows with the square of the velocity, so the same 60 gpm in a 3 in pipe instead of a 2 in pipe runs at 2.72 ft/s instead of 6.13 ft/s and the total falls from 62.9 ft to 51.8 ft.
- How to read the result against a pump curve: look up the total dynamic head at your flow on the pump maker’s curve. A pump whose curve passes through that point, at or near its best efficiency, will deliver your flow. Many designers add a margin for wear and for the uncertainty of the pipe roughness; the page adds none.
- Outlet pressure: if the water has to arrive at a pressure, for example 20 psi for a sprinkler, add it in the pressure box. In the default case 20 psi adds 46.2 ft and takes the total to 109.1 ft.
- Velocity head: it is off by default. The NRCS handbook says it is small in most applications and is usually ignored. Turn it on to add v² ÷ 2g; here that is 0.6 ft on top of 62.9 ft.
- What this page does not check: suction conditions and NPSH, the operating point on a system curve, the choice of the pump, or fire-pump and sprinkler duties. Fittings and equipment losses are typed by you, because they depend on the product; the page supplies no K values or equipment losses.
To see the friction part of the head in more detail, with the smallest pipe for a pressure loss you allow, use the Pipe Friction Loss Calculator. If the pump fills a tank, the Tank Volume Calculator gives its capacity, and the Pipe Volume Calculator gives the water the pipe holds. This page gives a head and power estimate for water in one pipe size; it does not check suction conditions or NPSH, and it is not a pump selection or a fire-pump calculation.
Worked example
Pump 60 gpm of water at 68 °F (20 °C) up 50 ft, to an open outlet, through 200 ft of 2 in PVC pipe (suction and discharge together), no fittings, no equipment loss, velocity head left out.
- Flow = 60 gpm = 3.785 L/s; inside diameter = 2 in = 50.8 mm
- Velocity = flow ÷ (π × D² ÷ 4) = 6.13 ft/s (1.87 m/s); Reynolds number from the water at 20 °C: density 998.1 kg/m³, viscosity 1.002 mPa·s, turbulent
- Friction head, Darcy-Weisbach with the Colebrook-White factor f = 0.0184: f × (L ÷ D) × v² ÷ (2g) = 12.9 ft (3.93 m)
- Static head = 50.0 ft (15.2 m); pressure head = 0 (open outlet); equipment head = 0
- Total dynamic head = 50.0 ft + 12.9 ft = 62.9 ft (19.2 m), about 27.2 psi of water pressure
- Water power = ρ × g × Q × TDH = 0.952 hp (0.710 kW)
- Shaft power, with a made-up efficiency of 65% (replace it with the figure on your pump curve) = 0.952 hp ÷ 0.65 = 1.47 hp
The same flow through a 3 in pipe runs at 2.72 ft/s and needs 51.8 ft of head, so the friction part falls from 12.9 ft to 1.84 ft while the 50.0 ft of lift stays. With a total fittings coefficient K of 6 in the 2 in pipe the friction part rises to 16.4 ft.
These are the same numbers the calculator shows when it first loads.
Method and formulas
TDH = Hstatic + Hpressure + Hfriction + Hequipment (+ v² ÷ 2g if you include velocity head)
Hpressure = p ÷ (ρ g) · Hfriction = (f × L ÷ D + ΣK) × v² ÷ (2g)
Water power Pw = ρ g Q TDH · Shaft power Ps = Pw ÷ η
- TDH
- Total dynamic head, in feet (metres) of water
- Hstatic
- Vertical distance from the source level to the delivery point; negative if the delivery is lower
- p
- Gauge pressure needed at the outlet
- f, L, D, v
- Darcy friction factor, total pipe length, inside diameter and mean velocity, as on the Pipe Friction Loss Calculator
- K
- Total loss coefficient of the fittings, typed by you
- ρ, g
- Density of water at your temperature and 9.80665 m/s²
- Q, η
- Flow rate and pump efficiency (a fraction); η is used only if you type it
The NRCS handbook (Chapter 8, section 623.0801) lists the parts of the total dynamic head as suction and discharge pipe friction, suction and discharge lift, system pressure, minor fitting loss and velocity head, and gives water horsepower as flow in gpm × head in ft × specific gravity ÷ 3,960, with brake horsepower as that divided by the pump efficiency. The page uses the same relations in SI with the density of water at the temperature you enter; for 20 °C water this differs from the 3,960 form by about 0.04%. Between a Reynolds number of 2,000 and 4,000 the page shows the friction head, the total and the power as a range, as the Pipe Friction Loss page does.
Assumptions and limits
- One pipe size and material for the whole run (suction and discharge together), full and flowing at a steady rate.
- A single liquid: water at the temperature entered; no slurry, gas or hot oil.
- Static head is measured between the water level pumped from and the delivery point, so a flooded or a lifting suction both work.
- Fittings enter as a total K, and filters, heaters and valves as a head, both typed by the reader; the page supplies none.
- Velocity head is left out unless the reader turns "Include velocity head" on (the handbook says it is usually ignored).
- A head and power estimate for choosing a pump from its curve; it is not a pump selection, system curve or design.
- Does not check suction conditions (NPSH available against required), cavitation, water hammer, pump curves or the operating point.
- Not a fire-pump or sprinkler-design calculation: those follow their own codes and acceptance tests.
- Friction in the transition zone (Reynolds number 2,000 to 4,000) has no reliable value: the page shows a range, as on the Pipe Friction Loss page.
- Ageing and scaling raise pipe roughness; allow margin when you choose the pump.
Reference tables
| Flow | 1.5 in | 2 in | 3 in | 4 in |
|---|---|---|---|---|
| 20 gpm | 3.6 | 0.9 | 0.1 | 0.0 |
| 40 gpm | 12.4 | 3.1 | 0.4 | 0.1 |
| 60 gpm | 25.8 | 6.4 | 0.9 | 0.2 |
| 80 gpm | 43.4 | 10.8 | 1.5 | 0.4 |
| 100 gpm | 65.2 | 16.2 | 2.3 | 0.6 |
Source: Calculated with the EngiFormula pump head engine (method v1.0): static head plus Darcy-Weisbach friction with the Colebrook-White factor, PVC roughness 0.002 mm, water at 20 °C. 1 US gallon = 231 in³, 1 psi = 6,894.757 Pa, 1 hp = 550 ft·lbf/s, from NIST Special Publication 811 (2008 edition), Appendix B.
| Pressure (psi) | Head (ft of water) | Head (m of water) |
|---|---|---|
| 5 | 11.6 | 3.52 |
| 10 | 23.1 | 7.04 |
| 20 | 46.2 | 14.09 |
| 30 | 69.3 | 21.13 |
| 40 | 92.4 | 28.18 |
| 60 | 138.7 | 42.26 |
| 80 | 184.9 | 56.35 |
Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 623 Irrigation, Chapter 8 Irrigation Pumping Plants, Amendment 78, January 2016, section 623.0801 (total dynamic head and water horsepower, pages 8-7 and 8-8), with the values worked out by the EngiFormula engine for water at 20 °C.
| Flow | Total dynamic head | Water power (hp) |
|---|---|---|
| 20 gpm | 20 ft | 0.10 |
| 20 gpm | 60 ft | 0.30 |
| 20 gpm | 100 ft | 0.50 |
| 40 gpm | 20 ft | 0.20 |
| 40 gpm | 60 ft | 0.61 |
| 40 gpm | 100 ft | 1.01 |
| 60 gpm | 20 ft | 0.30 |
| 60 gpm | 60 ft | 0.91 |
| 60 gpm | 100 ft | 1.51 |
| 100 gpm | 20 ft | 0.50 |
| 100 gpm | 60 ft | 1.51 |
| 100 gpm | 100 ft | 2.52 |
Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 623 Irrigation, Chapter 8 Irrigation Pumping Plants, Amendment 78, January 2016, section 623.0801 (total dynamic head and water horsepower, pages 8-7 and 8-8), with the values worked out by the EngiFormula engine for water at 20 °C.
| Material | Roughness ε (mm) | Roughness ε (in) |
|---|---|---|
| PVC, PE or HDPE plastic pipe | 0.002 | 0.0000787 |
| Copper, brass or other drawn tubing | 0.0015 | 0.0000591 |
| Commercial or welded steel | 0.046 | 0.00181 |
| Ductile iron | 0.061 | 0.0024 |
| Galvanized iron | 0.15 | 0.00591 |
| Cast iron | 0.25 | 0.00984 |
| Concrete, smooth end of the range (0.3 mm) | 0.3 | 0.0118 |
| Concrete, rough end of the range (3 mm) | 3 | 0.118 |
Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 634 Hydraulics, Chapter 4 Pipe Flow, 1st Edition, February 2022, Figure 4-5 (absolute roughness). Concrete is given there as a range; both ends are listed. Inches are converted from millimetres at 25.4 mm per inch.
Charts and diagrams
Show chart data as a table
| Flow (gpm) | 2 in | 3 in | 4 in |
|---|---|---|---|
| 10 | 50.54 | 50.08 | 50.02 |
| 20 | 51.81 | 50.26 | 50.07 |
| 30 | 53.73 | 50.54 | 50.14 |
| 40 | 56.23 | 50.89 | 50.23 |
| 50 | 59.29 | 51.33 | 50.34 |
| 60 | 62.89 | 51.84 | 50.46 |
| 80 | 71.65 | 53.08 | 50.78 |
| 100 | 82.42 | 54.6 | 51.16 |
| 120 | 95.14 | 56.39 | 51.6 |
Source: Calculated with the EngiFormula pump head engine (method v1.0): static head plus Darcy-Weisbach friction with the Colebrook-White factor, PVC roughness 0.002 mm, water at 20 °C. 1 US gallon = 231 in³, 1 psi = 6,894.757 Pa, 1 hp = 550 ft·lbf/s, from NIST Special Publication 811 (2008 edition), Appendix B.
Common uses
Irrigation and water supply
Enter the lift, the pipe and the pressure the sprinklers or the emitters need to get the head to look up on the pump curve.
Filling a tank or a reservoir
Use the height to the top of the tank as the static head, and add the pressure only if the tank is closed.
Pool and spa pumps
Type the filter, heater and valve losses from their maker’s data in the equipment box. The page gives no equipment values of its own.
Comparing pipe sizes
Change the inside diameter and watch the friction head and the power change while the lift stays the same.
Checking a result from another tool
The working shows each step, so you can compare the head, the friction factor and the power with a spreadsheet or a pump maker’s sizing tool.
Frequently asked questions
What is total dynamic head?
It is the total energy, per unit weight of water, that a pump has to add to move the flow: the lift, the pressure needed at the outlet, the friction in the pipe and fittings, the loss of equipment in the line and, if you count it, the velocity head. For 60 gpm up 50 ft through 200 ft of 2 in PVC it is 62.9 ft.
How do you calculate total dynamic head?
Add the parts: TDH = static head + pressure head + friction head + equipment head. In the default case that is 50.0 ft of lift plus 12.9 ft of friction, for 62.9 ft, about 27.2 psi of water pressure. The working above the page shows each step.
What is the difference between static head and total dynamic head?
Static head is the lift alone, the vertical distance between the water levels. Total dynamic head adds the outlet pressure, the friction and the equipment loss, so it is always the larger number when water is flowing. Here the static head is 50.0 ft and the total is 62.9 ft.
How do I find the total dynamic head of a pool pump?
Use the same sum. Enter the lift (often near zero), the length and inside diameter of the pipe, the fittings as a total K, and type the filter, heater and valve losses from their maker’s data in the equipment box. The page does not supply equipment values, because they depend on the product and the flow.
How does pipe size change total dynamic head?
A larger pipe lowers the velocity, and friction grows with the square of the velocity, so the friction part drops fast. In the default case, a 3 in pipe instead of 2 in cuts the total from 62.9 ft to 51.8 ft. The lift stays the same.
How do I convert pressure in psi to feet of head?
Divide the pressure by the weight of water per unit volume. For water at 68 °F, 1 psi is 2.31 ft of head, so 20 psi is 46.2 ft. The pressure table above lists common values.
How much horsepower does my pump need?
The water power is flow × head × density × g; here it is 0.952 hp. The pump needs more at the shaft because it is not perfectly efficient: type the efficiency from the pump curve and the page divides by it. With a made-up 65% the shaft power would be 1.47 hp. The page assumes no efficiency until you enter one.
Does total dynamic head include NPSH?
No. NPSH is a separate check on the suction side, to make sure the pump does not cavitate. This page does not do that check, so confirm it with the pump maker’s NPSH required at your flow.
Sources and references
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 623 Irrigation, Chapter 8 Irrigation Pumping Plants (210-VI-NEH), Amendment 78, January 2016: the parts of the total dynamic head, the local loss equation, water and brake horsepower (pages 8-7 and 8-8).
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 634 Hydraulics, Chapter 4 Pipe Flow (210-634-H), 1st Edition, February 2022: Darcy-Weisbach, Colebrook-White, loss coefficients and Figure 4-5, the roughness values.
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 634, Chapter 1 General Concepts (210-634-H), 1st Edition, February 2022, Figure 1-9 (page 634-1.16): density and viscosity of water.
- NIST Special Publication 811, Guide for the Use of the International System of Units (SI), 2008 edition, Appendix B (exact values for the inch, foot, gallon, pound-force and horsepower).
About this calculator
Scope and disclaimer
The total dynamic head and the hydraulic and shaft power for water in one pipe size, from lift, outlet pressure, pipe friction, fittings and equipment loss you enter. It is not a pump selection, NPSH, system-curve, fire-pump or design tool.
This calculator gives information and preliminary estimates only. It is not professional design advice and does not replace the governing code, product instructions or a qualified professional's judgement for your project.