How to read the result
- The friction factor and Reynolds number: the Reynolds number (105,008 here) compares the push of the flow with the stickiness of the liquid. Below 2,000 the flow is smooth and laminar and the friction factor is 64 divided by the Reynolds number. Above 4,000 it is turbulent and the factor depends on the roughness of the pipe wall (0.026 per thousand of the diameter here), which the page solves with the Colebrook-White equation. The friction factor here is 0.01795.
- Why velocity matters most: the loss grows with the square of the velocity. The same 100 gpm through a 3 in pipe runs at 4.54 ft/s and loses 2.30 ft; through a 2 in pipe it runs at 10.21 ft/s and loses 16.21 ft, about 7.1 times as much.
- Fittings: elbows, valves and tees are added by their loss coefficient K, as K times the velocity head. The page supplies no K values: take them from your fitting supplier or design. With a total K of 5 the loss above rises from 2.30 ft to 3.90 ft.
- The transition zone: between a Reynolds number of 2,000 and 4,000 no reliable friction factor exists, because the flow can switch between smooth and turbulent. The page then shows the loss from the laminar value and from the turbulent value as a range, with a warning, and never one number. Change the diameter or the flow to leave the zone.
- What this page does not do: it counts the friction of a full, straight, round pipe. It does not add a height change or a pump, and it is not for fire hose, sprinkler, gas or compressed-air lines, which have their own methods. For a gravity pipe that is not full, use the Pipe Flow Calculator.
For a pipe that runs partly full by gravity, such as a storm drain, use the Pipe Flow Calculator, and to find how much liquid the same pipe holds, the Pipe Volume Calculator. This page covers a full pressure pipe only. To add the lift and the outlet pressure and get the head a pump must deliver, use the Pump Total Dynamic Head Calculator. For water in turbulent flow only, the Hazen-Williams Calculator gives a quick result from a C factor. It is not for fire-protection or gas lines.
Worked example
100 gpm of water at 68 °F (20 °C) through 100 ft of PVC pipe with a 3 in inside diameter, no fittings.
- Flow = 100 gpm = 0.00631 m³/s; inside diameter = 3 in = 76.2 mm
- Velocity = flow ÷ (π × D² ÷ 4) = 4.54 ft/s (1.38 m/s)
- Water at 20 °C: density 998.1 kg/m³, viscosity 1.002 mPa·s
- Reynolds number = 998.1 × 1.3834 × 0.0762 ÷ 0.001002 = 105,008, turbulent
- Roughness of PVC = 0.002 mm; relative roughness = 0.002 ÷ 76.2 = 0.000026
- Swamee-Jain starting value for f = 0.01785; Colebrook-White, solved by iteration: f = 0.01795
- Head loss = f × (L ÷ D) × v² ÷ (2g) = 0.01795 × (400.0) × 1.9139 ÷ (2 × 9.80665) = 2.30 ft (0.701 m)
- Pressure drop = ρ × g × head loss = 0.995 psi (6.86 kPa)
- Loss per 100 ft of this pipe = 2.30 ft (0.995 psi)
The same flow through a 2 in pipe runs at 10.21 ft/s and loses 16.21 ft, a drop of 7.01 psi. In cast iron instead of PVC, the 3 in pipe loses 3.59 ft rather than 2.30 ft. If you allow 5 psi over 100 ft, the smallest inside diameter for this flow is 2.15 in, and the next standard size up is the one to choose.
These are the same numbers the calculator shows when it first loads.
Method and formulas
hf = f × (L ÷ D) × v² ÷ (2g) · v = Q ÷ (π D² ÷ 4) · Re = ρ v D ÷ μ
Laminar (Re ≤ 2,000): f = 64 ÷ Re · Turbulent (Re ≥ 4,000): 1 ÷ √f = −2 log10[ ε ÷ (3.7 D) + 2.51 ÷ (Re √f) ] (Colebrook-White)
Fittings: hm = ΣK × v² ÷ (2g) · Pressure drop = ρ × g × (hf + hm)
- hf
- Head loss in the straight pipe, in feet (metres) of the liquid
- f
- Darcy friction factor, no unit
- L, D
- Pipe length and inside diameter, in the same unit
- v
- Mean velocity, ft/s (m/s)
- g
- 9.80665 m/s²
- Re
- Reynolds number; ρ is the density and μ the dynamic viscosity of the liquid
- ε
- Absolute roughness of the pipe wall, from the table below or typed by you
- K
- Total loss coefficient of the fittings, typed by you
The Colebrook-White equation has f on both sides, so the page solves it by Newton iteration, starting from the explicit Swamee-Jain estimate f = 0.25 ÷ [log10(ε ÷ 3.7D + 5.74 ÷ Re0.9)]². The NRCS handbook states that estimate is within 2 to 5% of Colebrook-White; the page uses the Colebrook solution itself. Water density and viscosity come from the NRCS table by linear interpolation between the 5 °C rows. In the size mode the page finds the smallest diameter whose loss does not exceed the limit, by repeated halving; from a Reynolds number of 2,000 it uses the turbulent factor there, which is the safer side.
Assumptions and limits
- Steady, fully developed flow of a single liquid in a full, round, straight pipe of constant diameter and roughness.
- Incompressible liquid (water or another liquid the reader describes); no gas, steam or slurry.
- Smooth, constant roughness for the chosen material; real pipe ages and scales, which raises roughness.
- Fittings enter only as a total K typed by the reader; the page supplies no K values.
- No elevation change and no pump: this is the friction part of the pressure change only.
- Reynolds number 2,000 to 4,000 (transition) has no reliable friction factor: the page shows the laminar and the turbulent value as a range, never one number.
- The Swamee-Jain start value is stated by the handbook to be within 2 to 5% of Colebrook-White; the page uses the Colebrook solution itself.
- Not for gases, steam, compressed air or slurries, and not for open-channel or partly full pipes (use the Pipe Flow Calculator).
- Not a fire-protection, sprinkler or fire-hose calculation: those codes (for example NFPA 13) prescribe their own method and coefficients, and fire-service hose tables differ.
- Not a pump or system design: elevation, pump curves, valves in detail, water hammer and local code are outside the page.
Reference tables
| Material | Roughness ε (mm) | Roughness ε (in) |
|---|---|---|
| PVC, PE or HDPE plastic pipe | 0.002 | 0.0000787 |
| Copper, brass or other drawn tubing | 0.0015 | 0.0000591 |
| Commercial or welded steel | 0.046 | 0.00181 |
| Ductile iron | 0.061 | 0.0024 |
| Galvanized iron | 0.15 | 0.00591 |
| Cast iron | 0.25 | 0.00984 |
| Concrete, smooth end of the range (0.3 mm) | 0.3 | 0.0118 |
| Concrete, rough end of the range (3 mm) | 3 | 0.118 |
Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 634 Hydraulics, Chapter 4 Pipe Flow, 1st Edition, February 2022, Figure 4-5 (absolute roughness). Concrete is given there as a range; both ends are listed. Inches are converted from millimetres at 25.4 mm per inch.
| Temperature (°C) | Temperature (°F) | Density (kg/m³) | Density (lb/ft³) | Viscosity (mPa·s = cP) |
|---|---|---|---|---|
| 0 | 32 | 999.8 | 62.42 | 1.781 |
| 10 | 50 | 999.7 | 62.41 | 1.307 |
| 20 | 68 | 998.1 | 62.31 | 1.002 |
| 30 | 86 | 995.7 | 62.16 | 0.798 |
| 40 | 104 | 992.2 | 61.94 | 0.653 |
| 50 | 122 | 988.0 | 61.68 | 0.553 |
| 60 | 140 | 983.2 | 61.38 | 0.474 |
| 70 | 158 | 977.8 | 61.04 | 0.413 |
| 80 | 176 | 971.8 | 60.67 | 0.364 |
| 90 | 194 | 965.3 | 60.26 | 0.315 |
| 100 | 212 | 958.4 | 59.83 | 0.282 |
Source: USDA Natural Resources Conservation Service, National Engineering Handbook Part 634, Chapter 1 General Concepts, 1st Edition, February 2022, Figure 1-9 (physical properties of water in SI units), page 634-1.16. Every 5 °C row is on the calculator; every 10 °C row is shown here. Fahrenheit and lb/ft³ are converted here.
| Flow | 2 in | 3 in | 4 in | 6 in |
|---|---|---|---|---|
| 25 gpm | 1.35 | 0.19 | 0.05 | 0.01 |
| 50 gpm | 4.64 | 0.66 | 0.17 | 0.02 |
| 100 gpm | 16.21 | 2.30 | 0.58 | 0.08 |
| 200 gpm | 57.35 | 8.05 | 2.01 | 0.29 |
| 400 gpm | 206.10 | 28.51 | 7.07 | 1.00 |
Source: Calculated with the EngiFormula friction loss engine (method v1.0): Darcy-Weisbach with the Colebrook-White friction factor, PVC roughness 0.002 mm, water at 20 °C, 100 ft of pipe. 1 US gallon = 231 in³, 1 psi = 6,894.757 Pa, from NIST Special Publication 811 (2008 edition), Appendix B.
Charts and diagrams
Show chart data as a table
| Flow (gpm) | 2 in | 3 in | 4 in |
|---|---|---|---|
| 20 | 0.91 | 0.13 | 0.03 |
| 40 | 3.11 | 0.45 | 0.11 |
| 60 | 6.44 | 0.92 | 0.23 |
| 80 | 10.82 | 1.54 | 0.39 |
| 100 | 16.21 | 2.3 | 0.58 |
| 150 | 33.89 | 4.78 | 1.2 |
| 200 | 57.35 | 8.05 | 2.01 |
| 250 | 86.42 | 12.07 | 3.01 |
| 300 | 120.96 | 16.84 | 4.19 |
| 350 | 160.88 | 22.32 | 5.54 |
| 400 | 206.1 | 28.51 | 7.07 |
Source: Calculated with the EngiFormula friction loss engine (method v1.0): Darcy-Weisbach with the Colebrook-White friction factor, PVC roughness 0.002 mm, water at 20 °C, 100 ft of pipe. 1 US gallon = 231 in³, 1 psi = 6,894.757 Pa, from NIST Special Publication 811 (2008 edition), Appendix B.
Common uses
Supply and irrigation lines
Enter the flow, the inside diameter, the length and the material to see the pressure you lose along the line.
Choosing a pipe size
Switch to “Smallest pipe diameter for an allowed pressure loss”, enter the loss you can allow, and take the next standard size above the answer.
Pump suction and discharge lines
Add the fittings as a total K to get the friction part of the head a pump has to overcome. Height changes are not included.
Other liquids
Choose “Another liquid” and type its density and viscosity, for example a glycol mix or an oil, to see the loss and the flow regime.
Checking a result from another tool
The page shows velocity, Reynolds number and friction factor, so you can compare each step with a Hazen-Williams result, a Moody chart or your own spreadsheet.
Frequently asked questions
What is friction loss in a pipe?
It is the pressure, or the equivalent height of liquid, that the flow loses to the pipe wall as it moves along. For 100 gpm through 100 ft of 3 in PVC pipe it is 2.30 ft, which is 0.995 psi. It grows with length and with the square of the velocity, and it falls as the diameter increases.
How do you calculate head loss in a pipe?
Find the velocity from the flow and the diameter, the Reynolds number from the velocity and the liquid, and the friction factor from the Reynolds number and the roughness. Then head loss = f × (L ÷ D) × v² ÷ (2g). For the default case that is 4.54 ft/s, a Reynolds number of 105,008, f = 0.01795 and a head loss of 2.30 ft. The working above the page shows each step.
What is the difference between Darcy-Weisbach and Hazen-Williams?
Hazen-Williams is a shortcut formula for water at ordinary temperatures in turbulent flow, with a single coefficient C for the pipe. Darcy-Weisbach works for any liquid and any flow regime, because it uses the friction factor, the roughness and the liquid’s own density and viscosity. This page uses Darcy-Weisbach, so its results can differ a little from a Hazen-Williams page for the same pipe.
What is the friction factor and how do you find it?
The Darcy friction factor f is the number that scales the loss in the Darcy-Weisbach equation. In laminar flow (Reynolds number up to 2,000) it is 64 ÷ Re. In turbulent flow (4,000 and above) it comes from the Colebrook-White equation, which the page solves for you; here it is 0.01795. Both come from the NRCS National Engineering Handbook Part 634, Chapter 4.
How does pipe roughness change the pressure loss?
A rougher wall means a higher friction factor and a larger loss. In the default case, copper (0.0015 mm) loses 2.29 ft, PVC (0.002 mm) 2.30 ft and cast iron (0.25 mm) 3.59 ft per 100 ft. Old pipe scales and gets rougher, so use a higher roughness for an aged line. The roughness table above lists the values.
How do I add the loss from fittings and valves?
Add up the loss coefficient K of each fitting and valve, and type the total into the K box. The page adds K × v² ÷ (2g) to the straight-pipe loss. A total K of 5 takes the default case from 2.30 ft to 3.90 ft. The page gives no K values, because they depend on the fitting: ask your supplier or use your design table.
Can I use this for a fire hose or a sprinkler system?
No. Fire-hose friction loss uses its own coefficients, and sprinkler systems follow fire-protection codes such as NFPA 13 with their own method. This page is for ordinary pressure pipe carrying water or another liquid, and it is not a gas, steam or compressed-air calculation.
Why does the page show a range in the transition zone?
Between a Reynolds number of 2,000 and 4,000 the flow is neither reliably smooth nor reliably turbulent, so no friction factor can be trusted. The page shows the loss worked out with the laminar value and with the turbulent value as the two ends of a range, and warns you. Changing the diameter or the flow moves the result out of the zone.
Sources and references
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 634 Hydraulics, Chapter 4 Pipe Flow (210-634-H), 1st Edition, February 2022: Darcy-Weisbach, Colebrook-White and Swamee-Jain equations (634.0403), the loss coefficient equation, and Figure 4-5, the roughness values.
- USDA Natural Resources Conservation Service, National Engineering Handbook, Part 634, Chapter 1 General Concepts (210-634-H), 1st Edition, February 2022, Figure 1-9 (page 634-1.16): density and viscosity of water.
- NIST Special Publication 811, Guide for the Use of the International System of Units (SI), 2008 edition, Appendix B (exact values for the inch, foot, gallon and pound-force).
- Colebrook (1939) and Swamee and Jain (1976) are named as the NRCS handbook cites them.
About this calculator
Scope and disclaimer
Friction head loss and pressure drop for a single liquid in a full, straight, round pressure pipe by the Darcy-Weisbach equation. It does not design a system, and it is not a fire-protection, gas or open-channel calculation.
This calculator gives information and preliminary estimates only. It is not professional design advice and does not replace the governing code, product instructions or a qualified professional's judgement for your project.